Title: ADS - Facility Designation Correction PDR Reference: 97060008 Originator Reference: ADSFD SARPs Document Reference: ADS SARPs, Sections 2.2.1.3, 2.2.2.3 Status: ADOPTED PDR Revision Date: 18/08/97 (ACCEPTED->PROPOSED) 20/10/97 (PROPOSED->RESOLVED) PDR Submission Date: 27/06/97 Submitting State/Organization: ATNP WG3/SG2 Submitting Author Name: Saccone, G Submitting Author E-mail Address: gsaccone@ccgate.hac.com Submitting Author Supplemental Contact Information: ph 1 604 821-5182, fx 1 604 279-5980 SARPs Date: IV1.1, March 97 SARPs Language: English Summary of Defect: The Facility Designation parameter can be four to eight characters instead of only eight characters. If not implemented, SARPs chapter 3 (Abstract Service) and chapter 4 (ASN.1) are inconsistent. Assigned SME: Sub-Volume II SME Proposed SARPs amendment: Change the following sections from: Notes to 2.2.1.3.4.7, 2.2.1.3.5.7, 2.2.1.3.6.7: Note.- This parameter contains the 8 character ICAO facility designation... Sections 2.2.1.3.4.7.1, 2.2.1.3.5.7.1, 2.2.1.3.6.7.1: The ICAO facility designation parameter value shall conform to an abstract value corresponding to an 8 character ICAO facility designation. Section 2.2.2.3.4.3.1: The ICAO Facility designation parameter value shall conform to the abstract syntax eight-character ICAO facility designation. To: Notes to 2.2.1.3.4.7, 2.2.1.3.5.7, 2.2.1.3.6.7: Note.- This parameter contains the 4 to 8 character ICAO facility designation... Sections 2.2.1.3.4.7.1, 2.2.1.3.5.7.1, 2.2.1.3.6.7.1: The ICAO facility designation parameter value shall conform to an abstract value corresponding to a 4 to 8 character ICAO facility designation. Section 2.2.2.3.4.3.1: The ICAO Facility designation parameter value shall conform to the abstract syntax four- to eight-character ICAO facility designation. SME Recommendation to CCB: - CCB Decision: CCB-2(Langen): ACCEPTED atnp_ccb_chair: RESOLVED (20/10/97)