Title: CM - Timer Activation PDR Reference: 98070001 Originator Reference: timer.txt SARPs Document Reference: CM SARPs, sections 2.1.5.3.3.4.1, 2.1.5.3.3.8.2, figures 2.1.5-6, 2.1.5-8 and 2.1.5-10, tables 2.1.5-1 and 2.1.5-2. Status: RESOLVED Impact : C (Clarification) 28/09/98 (PROPOSED -> RESOLVED) 07/09/98 (ACCEPTED -> PROPOSED) PDR Revision Date: 17/08/98 (SUBMITTED -> ACCEPTED) PDR Submission Date: 08/07/98 Submitting State/Organisation: CENA/CHARME Submitting Author Name: Jean, M. Submitting Author E-mail Address: jean@cenatls.cena.dgac.fr Submitting Author Supplemental Contact Information: Tel: +33 5 62 25 95 89 Fax: +33 5 62 25 95 99 SARPs Date: ICAO Edition 2.2 (Rio) SARPs Language: English Summary of Defect: When the CM-ground-user invokes the CM-contact request primitive with no dialogue in place, the CM-ground-ASE invokes the D-START request primitive and the timer t-contact is activated. Likewise, when the user invokes a CM-contact request primitive with a dialogue in place, the timer t-contact has to be activated. Assigned SME: Sub-Volume II SME Proposed SARPs amendment: 1/ In figures 2.1.5-6, 2.1.5-8 and 2.1.5-10: add an arrow between D-DATA req and D-DATA ind to represent the timer t-contact in the figure. 2/ In section 2.1.5.3.3.4.1, replace: a) invoke CM-contact service confirmation... b) enter the DIALOGUE state. by : a) stop timer t-contact, b) invoke CM-contact service confirmation... c) enter the DIALOGUE state. 3/ In section 2.1.5.3.3.8.2, replace: b) ... parameter value, and c) enter the CONTACT DIALOGUE state. by : b) ... parameter value, c) start timer t-contact and d) enter the CONTACT DIALOGUE state. 4/ In Table 2.1.5.-1, replace cell (CM-contact, Timer Start Event) from D-START request to: D-START request D-DATA request and cell (CM-contact, Timer Stop Event) from D-START confirmation to: D-START confirmation D-DATA indication 5/ In table 2.1.5-2, add in cell (event=CM-Contact request/state=DIALOGUE): start timer t-contact and in cell (event=D-DATA Indication/state=CONTACT DIALOGUE): stop timer t-contact SME Recommendation to CCB: - CCB Decision: atnp_ccb_chair: SUBMITTED (06/07/98) atnp_ccb_chair: ACCEPTED (17/08/98) CCB-7 (Bordeaux): RESOLVED (28/09/98)