Title: CM - Facility Designation User Requirements Correction PDR Reference: 98090005 Originator Reference: SARPs Document Reference: CM SARPs, Sections 2.1.7.1.1.1 - 2.1.7.1.1.7, 2.1.7.1.2, 2.1.7.1.3.4, 2.1.7.2.2.6 - 2.1.7.2.2.7, 2.1.7.2.3.1, 2.1.7.2.6.5 Status: RESOLVED Impact : D (Minor) PDR Revision Date: 28/09/98 (PROPOSED -> RESOLVED) 22/09/98 (SUBMITTED -> ACCEPTED -> PROPOSED) 18/09/98 (PDR renumbered from 98090003 to 98090005, note 2 added in item 4) PDR Submission Date: 17/09/98 Submitting State/Organization: ATNP WG3/SG2 Submitting Author Name: Saccone, G Submitting Author E-mail Address: gsaccone@west.raytheon.com Submitting Author Supplemental Contact Information: ph 1 604 821-5182, fx 1 604 279-5795 SARPs Date: IV2.3 (Doc 9705) SARPs Language: English Summary of Defect: This PDR supersedes PDR 98050020. This PDR addresses operational concerns over the use of the optional facility designation field of the CMLogonRequest (cf. the detailed description of the problem in PDR 98050020). In order to ensure that the facility designation field is used and interpreted in a consistent manner, changes to the user requirements of CM must be made. Assigned SME: Sub-Volume II SME Proposed SARPs amendments: 1/ In 2.1.7.1.1.1, change (deleted text) {new text}: 2) for applications that can be ground initiated: application name, version number, and address for all versions that can be supported,( and) d) {the facility designation of the facility with which the CM-air-user wishes to exchange application information (if required), and e)} flight information data as required by the ground system. 2/ Add note to 2.1.7.1.1.1 : facility designation Facility Designation Renumber 2.1.7.1.1.2 through 2.1.7.1.1.6 to 2.1.7.1.1.3 through 2.1.7.1.1.7. 3/ Add 2.1.7.1.1.2 , [text bold]: 2.1.7.1.1.2 [Recommendation.] - facilityDesignation CMLogonRequest Facility Designation 4/ Add notes to 2.1.7.1.1.7 : facilityDesignation CMLogonRequest Logon Response facilityDesignation CMLogonRequest Logon Response Facility Designation facilityDesignation LogonRequest Logon Response : Update Information Facility Designation 6/ Add the following to the note of 2.1.7.1.3.4 : < However, the facility designation will not be provided as part of the> CMLogonRequest Renumber 2.1.7.2.2.6 and 2.1.7.2.2.7 to 2.1.7.2.2.8 and 2.1.7.2.2.9 7/ Add 2.1.7.2.2.6 : 2.1.7.2.2.6 If the facility designation is present in the> Logon Request CMLogonResponse 8/ Add note to 2.1.7.2.2.6 : 9/ Add 2.1.7.2.2.7 : 2.1.7.2.2.7 If the facility designation is not present in the parameter, then the application information contained in the shall correspond to the responding CM-ground-user's facility designation. 10/ Add note to 2.1.7.2.3.1 : 11/ Change 2.1.7.2.6.5 [text bold] (deleted text) {new text}: 2.1.7.2.6.5 {[Recommendation.] -} Forward Request SME Recommendation to CCB: - CCB Decision: atnp_ccb_chair: ACCEPTED (22/09/98) CCB-7 (Bordeaux): RESOLVED (28/09/98)