Title: CM - Timers Need To Be Reset PDR Reference: 98120005 Originator Reference: acicm03 SARPs Document Reference: CM SARPs, Section 2.1.5.4.5.2 and Table 2.1.5-2 Status: RESOLVED Impact : D (Minor) PDR Revision Date: 21/01/99 (PROPOSED -> RESOLVED) 18/01/99 (ACCEPTED -> PROPOSED) 14/12/98 (SUBMITTED -> ACCEPTED) PDR Submission Date: 03/12/98 Submitting State/Organization: AIRSYS ATM (ACI) Submitting Author Name: Ilkiewicz, M / Stokes, S Submitting Author E-mail Address: michel.ilkiewicz@cdv.vly.sextant. thomson-csf.com, shawn.stokes@atnsi.com Submitting Author Supplemental Contact Information: SARPs Date: IV2.3 (Doc 9705 Ed1) SARPs Language: English Summary of Defect: Section 2.1.5.4.5.2 covers the case where a D-START confirmation is received to be aborted for the following two cases: 1) Result is "rejected (transient)" or 2) Reject source is "DS provider". In addition to invoking the CM-provider-abort indication, the timers should be reset (t_Update or t_Contact or t_Forward). Assigned SME: Sub-Volume II SME Proposed SARPs amendment: 1/ Add in section 2.1.5.4.5.2 a new item a) [note that this section has changed due to PDR 98050002] from: 2.1.5.4.5.2 If the CM-ASE receives a D-START confirmation with the D-START parameter having the abstract value of "rejected (transient)" or if the D-START parameter has the abstract value of "DS provider", the CM-ASE shall: a) if the CM-user is an active user, invoke CM-provider-abort service indication with the abstract value "communication-service-error" APDU as the CM-provider-abort Reason parameter value. To: 2.1.5.4.5.2 If the CM-ASE receives a D-START confirmation with the D-START parameter having the abstract value of "rejected (transient)" or if the D-START parameter has the abstract value of "DS provider", the CM-ASE shall: a) stop all timers, and b) if the CM-user is an active user, invoke CM-provider-abort service indication with the abstract value "communication-service-error" APDU as the CM-provider-abort Reason parameter value. 2/ In Table 2.1.5-2, Cells "CM-user-abort Request", "D-ABORT Indication Originator is 'provider'", "D-ABORT Indication Originator is 'user'", "D-P-ABORT Indication" rows, "CONTACT DIALOGUE" column, add to each: Stop timer tcontact 3/ Cell (Tcontact Expires,CONTACT DIALOGUE), change: cannot occur to: D-ABORT request CM-provider-abort indication IDLE Impact on interoperability: None. On receipt of a negative D-START, the ASE instance is stopped anyway, stopping implicitly the running timers. This PDR is needed for completeness. SME Recommendation to CCB: CCB Decision: atnp_ccb_chair (SUBMITTED): 03/12/98 atnp-ccb_chair (ACCEPTED): 14/12/98 CCB-8 (Honolulu) : 19/01/98 (PROPOSED) CCB-8a (Honolulu) : 21/01/99 (RESOLVED)